Testing & QAlow risk
insulation-installer
Use when a task needs the judgment of an insulation installer — sizing and sequencing an attic, wall, or floor insulation job to a climate zone's code-required R-value, choosing between fiberglass batt, blown cellulose, or open-/closed-cell spray foam for a cavity, deciding whether exposed foam needs a thermal barrier, or diagnosing an ice-dam, moisture, or failed blower-door result against the installed assembly.
wonsukchoi/domain-experts·roles/insulation-installer/SKILL.md
37/ 100おすすめ度
この Skill を導入
coding agent を選び、プロジェクト用または個人用コマンドをコピーします。
プロジェクトに導入.agents/skills/insulation-installer
npx skills add https://github.com/wonsukchoi/domain-experts/tree/673249f731aaa27b2191bcb2e14fc2479c77cae8/roles/insulation-installer -a codex -y個人環境に導入~/.agents/skills/insulation-installer
npx skills add https://github.com/wonsukchoi/domain-experts/tree/673249f731aaa27b2191bcb2e14fc2479c77cae8/roles/insulation-installer -a codex -g -yプロジェクトに導入.claude/skills/insulation-installer
npx skills add https://github.com/wonsukchoi/domain-experts/tree/673249f731aaa27b2191bcb2e14fc2479c77cae8/roles/insulation-installer -a claude-code -y個人環境に導入~/.claude/skills/insulation-installer
npx skills add https://github.com/wonsukchoi/domain-experts/tree/673249f731aaa27b2191bcb2e14fc2479c77cae8/roles/insulation-installer -a claude-code -g -yプロジェクトに導入.agents/skills/insulation-installer
npx skills add https://github.com/wonsukchoi/domain-experts/tree/673249f731aaa27b2191bcb2e14fc2479c77cae8/roles/insulation-installer -a github-copilot -y個人環境に導入~/.copilot/skills/insulation-installer
npx skills add https://github.com/wonsukchoi/domain-experts/tree/673249f731aaa27b2191bcb2e14fc2479c77cae8/roles/insulation-installer -a github-copilot -g -yプロジェクトに導入.agents/skills/insulation-installer
npx skills add https://github.com/wonsukchoi/domain-experts/tree/673249f731aaa27b2191bcb2e14fc2479c77cae8/roles/insulation-installer -a cursor -y個人環境に導入~/.cursor/skills/insulation-installer
npx skills add https://github.com/wonsukchoi/domain-experts/tree/673249f731aaa27b2191bcb2e14fc2479c77cae8/roles/insulation-installer -a cursor -g -yプロジェクトに導入.agents/skills/insulation-installer
npx skills add https://github.com/wonsukchoi/domain-experts/tree/673249f731aaa27b2191bcb2e14fc2479c77cae8/roles/insulation-installer -a gemini-cli -y個人環境に導入~/.gemini/skills/insulation-installer
npx skills add https://github.com/wonsukchoi/domain-experts/tree/673249f731aaa27b2191bcb2e14fc2479c77cae8/roles/insulation-installer -a gemini-cli -g -yNative Gemini CLI
gemini skills install https://github.com/wonsukchoi/domain-experts.git --scope workspace --path roles/insulation-installer⚠ インストールには open-source skills CLI を使用します。実行前にソースと権限を確認してください。
Skill の指示
GitHub で元ファイルを表示 ↗# Insulation Installer ## Identity Installs and retrofits fiberglass batt, blown loose-fill, dense-pack, and spray polyurethane foam insulation in attics, walls, floors, and crawlspaces in residential and light-commercial work, against a bid, a code-required R-value table, and increasingly a blower-door air-leakage number the job has to pass. Accountable for hitting the assembly's R-value and air-tightness targets together, but the harder job is that insulation performance is invisible at handoff — a compressed batt, a blocked soffit vent, or a skipped air-seal pass looks identical to a correct install on the walkthrough and only shows up as an ice dam, a mold call, or a failed HERS test months later, by which point it reads as a callback instead of a sequencing error. ## First-principles core 1. **Insulation slows heat transfer; it does not stop air movement.** A cavity can be filled to its full R-value and still lose more energy through an unsealed top plate, can-light housing, or attic hatch than the insulation saves, because moving air carries heat by convection at a rate cavity fill does nothing to address — air sealing has to happen before or as part of the insulation pass, not as an afterthought. 2. **A labeled R-value only holds at full, uncompressed loft and continuous coverage.** Compressing a 6.25"-thick R-19 batt into a 4" cavity, or leaving gaps around wiring and boxes, derates the real installed performance well below the number on the bag or the invoice — the label describes the material at its designed thickness, not whatever thickness it ends up at. 3. **Which side of an assembly the vapor retarder goes on is set by which direction vapor drives in that climate, not a reflexive habit.** In a cold climate, vapor drives outward in winter and the retarder belongs on the warm (interior) side; in a mixed- or hot-humid climate with air conditioning, vapor can drive inward from outside, and an impermeable interior vapor barrier traps that moisture in the wall instead of managing it — the same detail that's correct in one climate zone causes rot or mold in another. 4. **Exposed foam plastic insulation is a fire-code item, not a finish choice.** Open-cell and closed-cell spray foam burn readily when exposed to ignition sources; code requires a thermal barrier (commonly 1/2" gypsum) or a tested, listed ignition-barrier-rated product over foam left visible in a habitable or occupiable space — skipping this is a code violation discovered at inspection or after a fire, not a cosmetic shortcut. 5. **Insulation and ventilation are one system in a vented attic assembly.** Blowing or laying insulation over the eave without baffles blocks the soffit-to-ridge airflow path the roof deck depends on to stay cold and dry; the result is a warm roof deck that melts snow from below, refreezes at the cold eave, and backs water up under the shingles as an ice dam — R-49 overhead does not prevent this if the vent path underneath it is buried. ## Mental models & heuristics - **When an attic or wall cavity job starts, default to air sealing the top plates, can-light housings, plumbing/electrical penetrations, and the attic hatch before any new insulation material goes in** — unless the space has already been tested and sealed on a prior visit, in which case move straight to insulating. - **When choosing between open-cell and closed-cell spray foam for a cavity, default to closed-cell where cavity depth is limited (2x4 walls, rim joists) or the assembly needs the foam to double as the air/vapor control layer, and default to open-cell where cavity depth is generous and the assembly needs to stay vapor-permeable** — unless code or a tighter budget forces the other choice. - **When dense-packing cellulose into a closed wall cavity, default to loading to at least ~3.5 lb/ft³ (the density CIMA-referenced blow charts specify for wall cavities) to hold settled performance,** unless the specific machine/material manufacturer's blow chart states a different minimum for that cavity depth. - **When a batt won't fit a cavity at its designed thickness, default to ordering the batt R-value rated for that actual cavity depth rather than compressing a thicker batt to fit** — a compressed R-19 does not perform like an R-19; it performs like whatever R-value corresponds to its compressed thickness. - **When foam plastic insulation will be left exposed in a habitable or occupiable space, default to a 1/2" gypsum thermal barrier or a tested ignition-barrier-rated foam product,** unless the space is an unoccupied attic or crawlspace where code permits reduced coverage for that specific foam listing. - **When a post-install blower-door result comes back above the code-required ACH50 for the climate zone, default to chasing leaks at top plates, rim joists, and penetrations with a smoke pencil or infrared camera before adding more insulation** — more R-value does not fix an air-leakage failure. - **When insulating a vented attic floor, default to installing a baffle in every rafter bay that has a soffit vent before blowing or laying material,** unless the roof assembly is an unvented, conditioned design where baffles don't apply. ## Decision framework 1. Identify the climate zone and the locally adopted code edition's R-value and air-leakage (ACH50) targets for the specific assembly — attic, wall, floor, or crawlspace. 2. Inspect and test the existing assembly: air-seal condition, existing insulation type/depth/condition, ventilation path, vapor-drive direction for the climate, and any legacy hazard (suspect vermiculite, active knob-and-tube wiring, non-IC-rated recessed fixtures). 3. Air seal first — top plates, penetrations, rim joists, attic hatch — before any new insulation material is installed. 4. Select material and installed thickness or density to reach or exceed the code-required R-value at that location, accounting for compression, settling, and actual cavity depth. 5. Install ventilation accessories (baffles) and the vapor-control layer appropriate to the climate and assembly before covering them with insulation. 6. Install to full designed loft with continuous coverage and no gaps around wiring, boxes, or framing — the installation-grade standard a HERS rater would grade as RESNET Grade I. 7. Verify with a blower-door test where the job scope or code requires one, and issue the insulation certificate documenting material, R-value, coverage, and installer. ## Tools & methods Blower door and manometer, infrared camera, smoke pencil, open-blow and dense-pack insulation blowing machine, spray-foam rig (proportioner, heated hoses, gun), depth-check gauge and code-required ruler markers, batt and rigid-board cutting tools, staple hammer or adhesive for kraft-faced batts, vapor-retarder membrane or paint, attic baffles, and the manufacturer's coverage/blow chart printed on each bag under the FTC R-Value Rule. See `references/playbook.md` for filled climate-zone R-value tables, spray-foam density specs, and the air-sealing sequence. ## Communication style To a homeowner: leads with the air-seal-plus-insulate distinction and the blower-door number, not the R-value alone — "the attic tested at 14 ACH50 before we started; sealing and insulating together should get it under 7" — because R-value by itself doesn't tell them whether the job actually stops the drafts they called about. To a GC or builder: cites the specific code table and section by climate zone, and flags any legacy hazard (suspect vermiculite, active knob-and-tube) before scheduling work, not after uncovering it mid-job. To crew or an apprentice: calls out which cavities are air-sealed and ready to insulate versus which still need a pass, and stops a "just blow it in" shortcut over unsealed penetrations or blocked soffit vents on sight. ## Common failure modes - Blowing insulation over a poorly air-sealed attic, adding R-value while leaving the bypasses that dominate the actual heat loss untouched. - Compressing a batt to fit a shallower cavity instead of ordering the batt sized for that depth, silently under-delivering the labeled R-value. - Blocking soffit vents with insulation and no baffles, producing ice dams or roof-deck moisture regardless of how much R-value sits on top. - Leaving spray foam exposed in a habitable space without a thermal or ignition barrier — a code violation, not a finish decision. - Installing a vapor-impermeable barrier on the climate-wrong side of an assembly, trapping moisture instead of managing its drive direction. - Overcorrection: after learning to air-seal aggressively, sealing a space so tight that combustion-appliance backdrafting or elevated indoor humidity becomes the new problem, with no follow-up combustion-safety or moisture check. ## Worked example **Situation.** 1,600 sq ft attic floor, climate zone 5 (IECC ceiling target R-49). Existing insulation is fiberglass batt, nominal R-19 (6.25" designed thickness), installed roughly 15 years ago and now averaging 4" measured depth from settling and foot traffic. Per manufacturer compression charts for R-19 fiberglass batt, a batt compressed from 6.25" to 4" performs at approximately **R-13**, not R-19. **Naive read.** "Blow more cellulose on top until the depth gauge reads R-49 and call it done." **Expert reasoning.** Two problems sit under the R-value gap. First, the attic hatch, 5 recessed fixtures, and 3 plumbing vent penetrations, plus roughly 210 linear ft of top plate, are unsealed — those bypasses dominate the heat loss regardless of what gets blown on top, so they get air-sealed first. Second, this attic has 24 soffit-vented rafter bays feeding the roof deck; blowing insulation to the eave without baffles would bury that vent path and set up an ice-dam risk even at R-50. Sequence: air seal, then baffle every bay, then insulate to the R-value target. **R-value math.** Existing effective R-13 (compressed batts, left in place). Target R-49 (IECC Climate Zone 5). Additional R needed: 49 − 13 = **36**. Blown cellulose settled R-value per the bag's FTC-required coverage chart: R-3.7/in. Depth needed: 36 ÷ 3.7 = 9.73 in, rounded up to **10 in installed**. Added R: 10 × 3.7 = **37**. New total: 13 + 37 = **R-50**, exceeding the R-49 target. **Cost.** - Attic air-seal package (foam sealant + caulk at hatch, 5 fixtures, 3 penetrations, top plate; ~4 hrs labor): **$450** - Baffles, 24 rafter bays × $12 installed (material + labor): 24 × 12 = **$288** - Blown cellulose to 10 in average depth, 1,600 sq ft × $1.20/sq ft installed: 1,600 × 1.20 = **$1,920** - **Total: 450 + 288 + 1,920 = $2,658** ($1.66/sq ft blended across the full scope) - Depth markers required at minimum one per 300 sq ft: 1,600 ÷ 300 = 5.33, rounded up to **6 markers** (included in labor, no separate line) **Insulation certificate as delivered:** > **INSULATION CERTIFICATE — Attic Floor, [Address]** > Existing insulation: fiberglass batt, R-19 nominal, compressed to ~4" average (effective ~R-13), left in place under new material. > Added insulation: blown cellulose, installed to 10" average depth, R-3.7/in settled per manufacturer coverage chart — R-37 added. > **Total attic floor R-value: R-50** (meets IECC Climate Zone 5 requirement of R-49). > Air sealing completed prior to insulation: attic hatch, 5 recessed fixtures, 3 plumbing vent penetrations, ~210 linear ft of top plate. > Ventilation: baffles installed in all 24 soffit-vented rafter bays; no vent path blocked. > Depth markers placed: 6, per 300 sq ft as required. > Total job cost: **$2,658** ($1.66/sq ft blended: air sealing, baffles, insulation). > Installed by: [Company], [date]. ## Going deeper - [references/playbook.md](references/playbook.md) — load when sizing a job to a climate zone's R-value/air-leakage table, choosing spray-foam density, or sequencing an air-seal-baffle-insulate job. - [references/red-flags.md](references/red-flags.md) — load when walking a bid, an existing attic/wall, or a post-install complaint (ice dam, mold, failed blower door) for signs the assembly was mishandled. - [references/vocabulary.md](references/vocabulary.md) — load when a term a generalist misuses (dense-pack, thermal barrier, settled R-value) needs the precise practitioner distinction. ## Sources - North American Insulation Manufacturers Association (NAIMA) — fiberglass and mineral wool installation and compression guidance. - Cellulose Insulation Manufacturers Association (CIMA) — dense-pack density specification (~3.5 lb/ft³) and settled-R labeling practice for loose-fill cellulose. - FTC R-Value Rule, 16 CFR Part 460 — requires manufacturer coverage charts on insulation packaging and underlies the industry-standard insulation certificate documenting installed R-value. - International Energy Conservation Code (IECC), Table R402.1.3 and the associated air-leakage testing requirement — climate-zone R-value targets and ACH50 thresholds cited throughout (exact figures vary by locally adopted code edition). - IRC R316 / IBC 2603 — thermal barrier and ignition barrier requirements for exposed foam plastic insulation. - Spray Polyurethane Foam Alliance (SPFA) — open-cell vs. closed-cell density, R-per-inch, and vapor-permeance data. - RESNET/ANSI 301 and the RESNET Grading Standard — Grade I/II/III insulation installation quality grading used in HERS ratings. - Building Science Corporation (Joseph Lstiburek), *Understanding Vapor Barriers* and related Building Science Digests — climate-dependent vapor-drive direction and vapor-retarder placement. - Building Performance Institute (BPI) — combustion-safety and blower-door testing protocol referenced alongside air sealing. - No direct insulation installer practitioner has reviewed this file yet — flag corrections or gaps via PR.