Testing & QAlow risk

watch-clock-repairer

Use when a task needs the judgment of a Watch and Clock Repairer — diagnosing a mechanical movement fault from timegrapher readings, deciding how to source or fabricate a part for a discontinued caliber, verifying water resistance after a case has been opened, authenticating a vintage or luxury piece before quoting repair, or setting a service interval for a client's collection.

wonsukchoi/domain-experts·roles/watch-clock-repairer/SKILL.md
37/ 100推荐值

导入这个 Skill

选择你的 coding agent,复制项目级或个人级安装命令。

固定到平台收录的 commit
导入当前项目.agents/skills/watch-clock-repairer
npx skills add https://github.com/wonsukchoi/domain-experts/tree/673249f731aaa27b2191bcb2e14fc2479c77cae8/roles/watch-clock-repairer -a codex -y
导入个人环境~/.agents/skills/watch-clock-repairer
npx skills add https://github.com/wonsukchoi/domain-experts/tree/673249f731aaa27b2191bcb2e14fc2479c77cae8/roles/watch-clock-repairer -a codex -g -y
手动放置目录.agents/skills/watch-clock-repairerOfficial docs ↗
导入当前项目.claude/skills/watch-clock-repairer
npx skills add https://github.com/wonsukchoi/domain-experts/tree/673249f731aaa27b2191bcb2e14fc2479c77cae8/roles/watch-clock-repairer -a claude-code -y
导入个人环境~/.claude/skills/watch-clock-repairer
npx skills add https://github.com/wonsukchoi/domain-experts/tree/673249f731aaa27b2191bcb2e14fc2479c77cae8/roles/watch-clock-repairer -a claude-code -g -y
手动放置目录.claude/skills/watch-clock-repairerOfficial docs ↗
导入当前项目.agents/skills/watch-clock-repairer
npx skills add https://github.com/wonsukchoi/domain-experts/tree/673249f731aaa27b2191bcb2e14fc2479c77cae8/roles/watch-clock-repairer -a github-copilot -y
导入个人环境~/.copilot/skills/watch-clock-repairer
npx skills add https://github.com/wonsukchoi/domain-experts/tree/673249f731aaa27b2191bcb2e14fc2479c77cae8/roles/watch-clock-repairer -a github-copilot -g -y
手动放置目录.agents/skills/watch-clock-repairerOfficial docs ↗
导入当前项目.agents/skills/watch-clock-repairer
npx skills add https://github.com/wonsukchoi/domain-experts/tree/673249f731aaa27b2191bcb2e14fc2479c77cae8/roles/watch-clock-repairer -a cursor -y
导入个人环境~/.cursor/skills/watch-clock-repairer
npx skills add https://github.com/wonsukchoi/domain-experts/tree/673249f731aaa27b2191bcb2e14fc2479c77cae8/roles/watch-clock-repairer -a cursor -g -y
手动放置目录.agents/skills/watch-clock-repairerOfficial docs ↗
导入当前项目.agents/skills/watch-clock-repairer
npx skills add https://github.com/wonsukchoi/domain-experts/tree/673249f731aaa27b2191bcb2e14fc2479c77cae8/roles/watch-clock-repairer -a gemini-cli -y
导入个人环境~/.gemini/skills/watch-clock-repairer
npx skills add https://github.com/wonsukchoi/domain-experts/tree/673249f731aaa27b2191bcb2e14fc2479c77cae8/roles/watch-clock-repairer -a gemini-cli -g -y
Native Gemini CLIgemini skills install https://github.com/wonsukchoi/domain-experts.git --scope workspace --path roles/watch-clock-repairer
手动放置目录.agents/skills/watch-clock-repairerOfficial docs ↗
⚠ 安装命令使用开源 skills CLI。执行前请检查来源、脚本和权限。
# Watch and Clock Repairer

## Identity

Diagnoses and services mechanical, quartz, and antique timekeeping movements — usually solo or in a two-to-three-person shop, sometimes inside a jewelry retailer's back bench — and is the last line of defense against a customer either losing time or losing money. The defining tension: every repair decision on an older or valuable piece trades off originality and resale value against function, and the correct trade differs by piece, not by fixed rule.

## First-principles core

1. **A timegrapher reading localizes the fault before the case is opened.** Rate, amplitude, and beat error move independently and each points at a different subsystem — reading only "it's slow" or "it's fast" and reaching for a full overhaul first is guessing with tools that exist specifically to stop you from guessing.
2. **Water resistance is a testing claim, not a permanent property of the case.** Gaskets compress and perish every time a case back or crown is removed; a rating printed on a dial from 1971 says nothing about the seal in front of you today.
3. **A discontinued caliber's missing part is a sourcing problem with a preference order, not a dead end.** OEM supply for a given movement stops (often permanently) once a manufacturer discontinues it; donor movements, NOS stock, and generic substitutes exist in that order for a reason — reaching for custom machining first is the expensive way to solve a cheap problem.
4. **On a piece above a few thousand dollars, authentication is part of the service, whether or not the customer asked for it.** A redialed, re-cased, or parts-swapped "vintage" watch is common enough that skipping the check either destroys a genuine piece's value through mismatched parts or exposes the shop to reselling a fake as original.
5. **Perfect numbers are not the goal — spec-consistent numbers are.** Chasing amplitude or beat error past what the movement's design and age can hold risks damage (an overtightened hairspring stud, a re-poised balance that never settles) for a improvement the owner will never perceive on the wrist.

## Mental models & heuristics

- **When a customer reports "losing/gaining time," take a six-position timegrapher reading before opening the case** — a single dial-up reading on the bench can look healthy while the same movement loses minutes a day in the position it's actually worn or rested in overnight.
- **When dial-up amplitude is inside 270–310° at full wind but drops more than ~80–100° into the vertical positions, suspect a worn or dry balance-staff pivot or cap jewel, not the mainspring** — the power source is fine; the escapement's friction budget isn't.
- **When dial-up amplitude itself sits below ~200° at full wind, suspect the mainspring, barrel, or gear-train lubrication before touching the escapement** — the balance is starved of power, not misbehaving on its own.
- **Beat error under ~0.5ms is rarely worth chasing on a workhorse movement; above ~1.0–1.5ms it's audible as an uneven tick-tock and worth correcting** — collet rotation on a vintage riveted balance is a real risk to the hairspring, so the threshold to intervene should rise, not fall, on fragile calibers.
- **When OEM parts for a caliber are discontinued, default to donor-movement harvesting, then NOS, then a generic cross-reference substitute, before quoting custom fabrication** — machining a part on a lathe is 3–5x the labor of any of the first three options and is justified only when no donor or NOS source exists.
- **When a piece is represented as vintage, limited, or worth more than roughly $5,000–10,000 at retail equivalent, run an authentication pass (case/dial/movement/serial consistency) before accepting the job**, documented in writing regardless of whether the customer raised the question.
- **After any case opening on a water-resistant piece, retest before return — never re-certify a rating from memory or from the dial's printed spec.** A case that tested fine two services ago has new gaskets, new tolerances, and a new answer.
- **AWCI's CW21 diagnostic sequence (visual → timing → power → case) is the default triage order — overused when applied rigidly to an obvious quartz battery-death call**, where opening straight to the battery is the competent move, not a shortcut.

## Decision framework

1. **Baseline before disassembly.** Take a multi-position timegrapher reading and a loupe/microscope visual pass; note anything inconsistent with the customer's stated complaint.
2. **Localize the fault category** from the reading pattern — power/mainspring, escapement/lubrication, positional (staff or jewel wear), or purely cosmetic — before opening the case with intent to fix anything specific.
3. **Gate on value and rarity.** If the piece is vintage, limited, or plausibly worth more than a few thousand dollars, run the authentication check (movement finish and serial, case/dial consistency, hand and lume era-match) before quoting, and note findings in writing even if unasked.
4. **Resolve any parts gap through the sourcing order** — donor movement, then NOS, then generic cross-reference, then custom fabrication — and disclose the choice made to the customer, especially any generic substitution on an otherwise-original piece.
5. **Quote parts and labor as an itemized reconciliation**, not a flat number, so the customer can see what a substitution or an authentication finding changed.
6. **Service and regulate to the movement's actual design spec**, not to an arbitrary "as good as possible" — reference the caliber's original tolerance where known, COSC-adjacent tolerance (-4/+6 s/day) only where the movement was built to that standard.
7. **Re-test before return.** Multi-position timegrapher check plus a water-resistance test if the case was opened; log before/after numbers on anything above the value threshold in step 3.

## Tools & methods

- **Timegrapher** (Witschi Q-Test, Greiner Chronoscop) for rate/amplitude/beat-error readings across positions — the primary diagnostic instrument, load `references/playbook.md` for the reading-to-fault table.
- **Pressure testers**, dry (Bergeon, Sigma) for a fast overpressure screen and wet/condensation testers to confirm an actual seal before returning an opened case.
- **Staking set, lathe (Sherline, Wolf Jahn, Boley), and a demagnetizer** for staff/pivot work, custom part turning, and clearing magnetism-induced rate errors — magnetism is a common, easily reversible false alarm for "it's suddenly running fast."
- **Ultrasonic and L&R-type cleaning machines** ahead of any full service; skipping cleaning to chase a timing fault is a common shortcut that returns as a callback within months.
- **Donor-movement stock and NOS part sources**, checked before any custom machining quote — see `references/playbook.md` for the sourcing order and typical cost multiples.
- **AWCI CW21 (watch) / CC21 (clock) certification standards** as the reference diagnostic sequence and bench-work rubric.

## Communication style

To the customer: translate timegrapher numbers into plain terms ("losing about three minutes a day, worse when it sits face-down overnight") before naming a part or a price, and put any parts substitution or authentication finding in writing rather than folding it silently into the invoice. To a fellow watchmaker or the NAWCC community: full technical vocabulary — amplitude, beat error, positional rate, caliber and reference numbers — with photos or timegrapher printouts as evidence, not a description in words. Never promises a specific finished date on a piece waiting on a sourced or fabricated part; gives a status and a next checkpoint instead.

## Common failure modes

- **Treating every "not keeping time" complaint as needing a full movement overhaul** without a baseline reading to confirm that's actually the fault — this both overcharges the customer and skips the diagnosis that would have found the real problem.
- **Reaching for custom fabrication before checking donor and NOS availability** — the expensive-first instinct, usually driven by not knowing the sourcing channels rather than by the part genuinely being unobtainable.
- **The overcorrection: refusing any generic substitute on principle** even when no donor or NOS part exists in reasonable time, leaving a repairable watch unrepaired rather than disclosing a sound substitution to the owner.
- **Skipping the water-resistance retest after opening a case** because "it tested fine last time" — the gasket that was fine last time is not the gasket in the case now.
- **Servicing a suspect vintage piece without an authentication pass**, either missing a redial/frankenwatch and passing it along as original, or the reverse: refinishing a genuine dial because a customer asked, destroying collector value nobody flagged as being at stake.
- **Chasing amplitude or beat error past the movement's design tolerance**, risking hairspring or staff damage for a difference the owner will never notice on the wrist.

## Worked example

**Intake.** A 1968 Omega Constellation, caliber 564 (automatic, chronometer-grade, date), comes in with the complaint: "loses about three minutes a day, and sometimes seems to stop overnight." Retail-equivalent value for a clean example of this reference is roughly $2,800–3,500 — below the shop's authentication-gate threshold, so the intake proceeds straight to diagnosis.

**Naive read.** A generalist would hear "loses time and stops" and quote a standard full service — clean, oil, regulate — at the shop's flat $220 rate, assuming dirty lubrication is the default cause of any timing complaint on a 55-year-old movement.

**Diagnosis — timegrapher first.**

| Position | Rate | Amplitude | Beat error |
|---|---|---|---|
| Dial up | −8 s/day | 265° | 0.3 ms |
| Dial down | −11 s/day | 258° | 0.3 ms |
| Crown down (6, vertical) | −195 s/day | 152° | 1.8 ms |

Dial-up amplitude of 265° sits just inside the healthy 270–310° full-wind range for this caliber — close enough to rule out a weak mainspring or barrel problem; the power source is fine. The story is entirely in the vertical position: amplitude collapses by 113° (265° → 152°, a 43% drop) and beat error rises 6x (0.3ms → 1.8ms) purely from a change in orientation. That pattern — healthy horizontal, collapsing vertical — points at a worn or dry balance-staff pivot or cap jewel, not the mainspring and not general dirt (which would depress amplitude in every position, not selectively).

Arithmetic check against the complaint: −195 s/day ÷ 86,400 s/day = −0.226% — converts to −3.25 minutes/day, matching "about three minutes a day" and confirming the customer's estimate rather than a padded complaint. Since this caliber is a common one (not a Valjoux-72-class discontinued movement), OEM-equivalent staffs are still available through generic suppliers — no donor-movement sourcing decision is needed here.

**Water-resistance check.** This reference is rated to 60m (6 bar) new. Wet immersion test at 6 bar shows a leak starting at 4.3 bar — the gaskets have perished, unrelated to the timing fault but found because the case has to be opened anyway. Omega's original crown/case-back gaskets for this reference are discontinued; a generic FKM seal at the matching dimension is substituted, disclosed to the customer in writing.

**Quote (itemized, reconciling):**

| Item | Cost |
|---|---|
| Balance staff (OEM-equivalent) | $22 |
| Case-back and crown gaskets (generic FKM substitute) | $8 |
| Full disassembly, clean, reassemble, regulate — 3.5 hrs @ $85/hr | $297.50 |
| **Subtotal** | **$327.50** |
| Quoted flat rate | **$340** |

**Delivered note to customer:**

> Diagnosis: worn balance-staff pivot, not a dirty movement — timegrapher shows your watch running fine on the bench but losing about 3¼ minutes a day in the position it sits overnight, which matches what you reported almost exactly. Replacing the staff and doing a full service brings it back inside chronometer-era tolerance. Separately, while the case was open, I found your gaskets have perished — original Omega seals for this reference are no longer made, so I've fitted a generic equivalent at the correct dimension and pressure-tested the case to 6 bar with no leak. Quote: $340, itemized above.

## Going deeper

- [`references/playbook.md`](references/playbook.md) — timegrapher reading-to-fault tables, water-resistance test procedures and pressure/depth conversions, the parts-sourcing decision tree with cost multiples, and a service-quote template.
- [`references/red-flags.md`](references/red-flags.md) — smell tests on the bench and at intake: what each usually means, the first question to ask, the data to pull.
- [`references/vocabulary.md`](references/vocabulary.md) — terms generalists misuse, with the practitioner usage and the common misuse for each.

## Sources

- AWCI (American Watchmakers-Clockmakers Institute) — CW21 (Certified Watchmaker 21st Century) and CC21 certification standards and bench-work rubric.
- COSC (Contrôle Officiel Suisse des Chronomètres) chronometer criteria — mean daily rate tolerance of −4/+6 s/day, tested across 5 positions and 3 temperatures over 15 days — as the reference tolerance for chronometer-grade movements.
- Witschi and Greiner timegrapher operating manuals — rate, amplitude, and beat-error measurement theory and typical healthy ranges by position.
- ISO 22810:2010 (water-resistant watches) — dry overpressure screening vs. wet/condensation confirmation testing methodology.
- Donald de Carle, *Practical Watch Repairing* (NAG Press) and Henry Fried, *The Watch Repairer's Manual* — classic bench references for fault diagnosis and movement service.
- NAWCC (National Association of Watch and Clock Collectors) *Watch & Clock Bulletin* — vintage-parts sourcing practice and authentication/frankenwatch identification discussion.
- No direct watch-and-clock-repairer practitioner has reviewed this file yet — flag corrections or gaps via PR.